Knowledge Base

BLM License File Loading Order

How are license files read and in what order are they read when the BLM starts up? When the BLM starts up it locates any .lic file in its home directory (the directory containing the BLM executable) and loads them in ascending order. Duplicate feature lines are ignored if encountered in successive .lic files being …

BLM License File Loading Order Read More »

00718: BASIC Web Utility returns an incomplete set of HTTP headers

Title: BASIC Web Utility returns an incomplete set of HTTP headers Description: When using the Basis Web Utility, it’s possible to recieve and error like the following: CGI Error:The specified CGI application misbehaved by not returning a complete set of HTTP headers. The headers it did return are… Resolution: The error indicates that the browser never …

00718: BASIC Web Utility returns an incomplete set of HTTP headers Read More »

00750: FLEXlm error -17 “Cannot write data to License server”

Title: FLEXlm error -17 “Cannot write data to License server” Description: This error typically occurs when Windows 95/98 clients try to checkout a license from a BASIS License Manager (BLM) running on a SCO server. Always begin troubleshooting from the server side first, then move to the client.  Resolution: First, ensure that the TCP/IP configuration is …

00750: FLEXlm error -17 “Cannot write data to License server” Read More »

00645: Error 41 opening a sysprint device

Title: Error 41 opening a sysprint device Description: An error 41 can occur opening a sysprint device when the font selected and tmargin and lmargin values are being set on the alias line. Resolution: Remove the ‘font’, ‘tmargin’, and ‘lmargin’ on the alias line and the error goes away Last Modified: 03/27/2000 Product: Visual PRO/5 Operating System: N/A Error Number:41 BASIS …

00645: Error 41 opening a sysprint device Read More »

00787: Netware client GPF’s when trying to check out a license under NOVELL 5.0

Title: Netware client GPF’s when trying to check out a license under NOVELL 5.0 Description: Window 95/98 workstations using older Novell client kits may cause VPRO5 to GPF: VPRO5 caused an invalid page fault in module MSVCRT.DLL This behavior may occur when it attempts to request a license from the Basis.nlm installed on a Novell Netware 5 …

00787: Netware client GPF’s when trying to check out a license under NOVELL 5.0 Read More »

00992: FLEXlm error – 6

Title: FLEXlm error – 6 Description: A Single-User PRO/5 or VPRO/5 that is node-locked (license file indicates uncounted as number of users) cannot be upgraded to BBj products without contacting BASIS Sales. This error will occur when using a node locked single user BBj license file generated for PRO5 Rev 4+ with a BBj product. If …

00992: FLEXlm error – 6 Read More »

00069: Escape sequence to force a laser printer to print double-sided copies

Title: Escape sequence to force a laser printer to print double-sided copies Description: You can print duplex (both sides) on a laser printer via the escape sequences. On an HPLJ4Si, send <esc>&l1S before the data, and <esc>&l0S after the data.  Last Modified: 11/10/1998 Product: PRO/5 Operating System: All platforms BASIS structures five components of their technology into the BBx Generations.

Scroll to Top