Have a Question?
Print

00484: _FLIST.UTL or other utilities report an error 1

Title:

_FLIST.UTL or other utilities report an error 1

Description:

Running or calling _FLIST.UTL will result in an Error 1 if the Visual PRO/5 window is greater than 80×25. For example, if the Visual PRO/5 SYSWINDOW is setup for 80×29, an Error 1 will result. If the SYSWINDOW is changed to 80×25, the problem is corrected. 

Note that this issue may occur in other utilities such as _fix., as many of them use the ‘box’ mnemonic.

Resolution:

Many of these utilities rely on the window being 80×25. Therefore, the solution is to set the SYSWINDOW to 80 columns by 25 lines.



Last Modified: 03/31/1998 Product: Visual PRO/5 Operating System: Windows Error Number: 1